A-20
C70 Capacitor Bank Protection and Control System
GE Multilin
A.1 PARAMETER LISTS
APPENDIX A
A
10287
SRC 1 Ib Harm[13]
Amps
Source 1 phase B current fifteenth harmonic
10288
SRC 1 Ib Harm[14]
Amps
Source 1 phase B current sixteenth harmonic
10289
SRC 1 Ib Harm[15]
Amps
Source 1 phase B current seventeenth harmonic
10290
SRC 1 Ib Harm[16]
Amps
Source 1 phase B current eighteenth harmonic
10291
SRC 1 Ib Harm[17]
Amps
Source 1 phase B current nineteenth harmonic
10292
SRC 1 Ib Harm[18]
Amps
Source 1 phase B current twentieth harmonic
10293
SRC 1 Ib Harm[19]
Amps
Source 1 phase B current twenty-first harmonic
10294
SRC 1 Ib Harm[20]
Amps
Source 1 phase B current twenty-second harmonic
10295
SRC 1 Ib Harm[21]
Amps
Source 1 phase B current twenty-third harmonic
10296
SRC 1 Ib Harm[22]
Amps
Source 1 phase B current twenty-fourth harmonic
10297
SRC 1 Ib Harm[23]
Amps
Source 1 phase B current twenty-fifth harmonic
10306
SRC 1 Ic THD
---
Source 1 phase C current total harmonic distortion
10307
SRC 1 Ic Harm[0]
Amps
Source 1 phase C current second harmonic
10308
SRC 1 Ic Harm[1]
Amps
Source 1 phase C current third harmonic
10309
SRC 1 Ic Harm[2]
Amps
Source 1 phase C current fourth harmonic
10310
SRC 1 Ic Harm[3]
Amps
Source 1 phase C current fifth harmonic
10311
SRC 1 Ic Harm[4]
Amps
Source 1 phase C current sixth harmonic
10312
SRC 1 Ic Harm[5]
Amps
Source 1 phase C current seventh harmonic
10313
SRC 1 Ic Harm[6]
Amps
Source 1 phase C current eighth harmonic
10314
SRC 1 Ic Harm[7]
Amps
Source 1 phase C current ninth harmonic
10315
SRC 1 Ic Harm[8]
Amps
Source 1 phase C current tenth harmonic
10316
SRC 1 Ic Harm[9]
Amps
Source 1 phase C current eleventh harmonic
10317
SRC 1 Ic Harm[10]
Amps
Source 1 phase C current twelfth harmonic
10318
SRC 1 Ic Harm[11]
Amps
Source 1 phase C current thirteenth harmonic
10319
SRC 1 Ic Harm[12]
Amps
Source 1 phase C current fourteenth harmonic
10320
SRC 1 Ic Harm[13]
Amps
Source 1 phase C current fifteenth harmonic
10321
SRC 1 Ic Harm[14]
Amps
Source 1 phase C current sixteenth harmonic
10322
SRC 1 Ic Harm[15]
Amps
Source 1 phase C current seventeenth harmonic
10323
SRC 1 Ic Harm[16]
Amps
Source 1 phase C current eighteenth harmonic
10324
SRC 1 Ic Harm[17]
Amps
Source 1 phase C current nineteenth harmonic
10325
SRC 1 Ic Harm[18]
Amps
Source 1 phase C current twentieth harmonic
10326
SRC 1 Ic Harm[19]
Amps
Source 1 phase C current twenty-first harmonic
10327
SRC 1 Ic Harm[20]
Amps
Source 1 phase C current twenty-second harmonic
10328
SRC 1 Ic Harm[21]
Amps
Source 1 phase C current twenty-third harmonic
10329
SRC 1 Ic Harm[22]
Amps
Source 1 phase C current twenty-fourth harmonic
10330
SRC 1 Ic Harm[23]
Amps
Source 1 phase C current twenty-fifth harmonic
10339
SRC 2 Ia THD
---
Source 2 phase A current total harmonic distortion
10340
SRC 2 Ia Harm[0]
Amps
Source 2 phase A current second harmonic
10341
SRC 2 Ia Harm[1]
Amps
Source 2 phase A current third harmonic
10342
SRC 2 Ia Harm[2]
Amps
Source 2 phase A current fourth harmonic
10343
SRC 2 Ia Harm[3]
Amps
Source 2 phase A current fifth harmonic
10344
SRC 2 Ia Harm[4]
Amps
Source 2 phase A current sixth harmonic
10345
SRC 2 Ia Harm[5]
Amps
Source 2 phase A current seventh harmonic
10346
SRC 2 Ia Harm[6]
Amps
Source 2 phase A current eighth harmonic
10347
SRC 2 Ia Harm[7]
Amps
Source 2 phase A current ninth harmonic
10348
SRC 2 Ia Harm[8]
Amps
Source 2 phase A current tenth harmonic
10349
SRC 2 Ia Harm[9]
Amps
Source 2 phase A current eleventh harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 20 of 31)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Содержание UR Series C70
Страница 2: ......
Страница 10: ...x C70 Capacitor Bank Protection and Control System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 C70 Capacitor Bank Protection and Control System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 124: ...4 30 C70 Capacitor Bank Protection and Control System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 344: ...5 220 C70 Capacitor Bank Protection and Control System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 396: ...8 18 C70 Capacitor Bank Protection and Control System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 414: ...9 18 C70 Capacitor Bank Protection and Control System GE Multilin 9 1 OVERVIEW 9 THEORY OF OPERATION 9 ...
Страница 436: ...10 22 C70 Capacitor Bank Protection and Control System GE Multilin 10 4 SETTING EXAMPLE 10 APPLICATION OF SETTINGS 10 ...
Страница 547: ...GE Multilin C70 Capacitor Bank Protection and Control System B 79 APPENDIX B B 4 MEMORY MAPPING B ...
Страница 548: ...B 80 C70 Capacitor Bank Protection and Control System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Страница 586: ...D 10 C70 Capacitor Bank Protection and Control System GE Multilin D 1 OVERVIEW APPENDIXD D ...
Страница 598: ...E 12 C70 Capacitor Bank Protection and Control System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...