GE Multilin
C70 Capacitor Bank Protection and Control System
B-69
APPENDIX B
B.4 MEMORY MAPPING
B
F151
ENUMERATION: RTD SELECTION
F152
ENUMERATION: SETTING GROUP
0 = Active Group, 1 = Group 1, 2 = Group 2, 3 = Group 3
4 = Group 4, 5 = Group 5, 6 = Group 6
F155
ENUMERATION: REMOTE DEVICE STATE
0 = Offline, 1 = Online
F156
ENUMERATION: REMOTE INPUT BIT PAIRS
F157
ENUMERATION: BREAKER MODE
0 = 3-Pole, 1 = 1-Pole
F159
ENUMERATION: BREAKER AUX CONTACT KEYING
0 = 52a, 1 = 52b, 2 = None
F166
ENUMERATION: AUXILIARY VT CONNECTION TYPE
0 = Vn, 1 = Vag, 2 = Vbg, 3 = Vcg, 4 = Vab, 5 = Vbc, 6 = Vca
bitmask
RTD#
bitmask
RTD#
bitmask
RTD#
0
NONE
17
RTD 17
33
RTD 33
1
RTD 1
18
RTD 18
34
RTD 34
2
RTD 2
19
RTD 19
35
RTD 35
3
RTD 3
20
RTD 20
36
RTD 36
4
RTD 4
21
RTD 21
37
RTD 37
5
RTD 5
22
RTD 22
38
RTD 38
6
RTD 6
23
RTD 23
39
RTD 39
7
RTD 7
24
RTD 24
40
RTD 40
8
RTD 8
25
RTD 25
41
RTD 41
9
RTD 9
26
RTD 26
42
RTD 42
10
RTD 10
27
RTD 27
43
RTD 43
11
RTD 11
28
RTD 28
44
RTD 44
12
RTD 12
29
RTD 29
45
RTD 45
13
RTD 13
30
RTD 30
46
RTD 46
14
RTD 14
31
RTD 31
47
RTD 47
15
RTD 15
32
RTD 32
48
RTD 48
16
RTD 16
bitmask
value
bitmask
value
0
NONE
35
UserSt-3
1
DNA-1
36
UserSt-4
2
DNA-2
37
UserSt-5
3
DNA-3
38
UserSt-6
4
DNA-4
39
UserSt-7
5
DNA-5
40
UserSt-8
6
DNA-6
41
UserSt-9
7
DNA-7
42
UserSt-10
8
DNA-8
43
UserSt-11
9
DNA-9
44
UserSt-12
10
DNA-10
45
UserSt-13
11
DNA-11
46
UserSt-14
12
DNA-12
47
UserSt-15
13
DNA-13
48
UserSt-16
14
DNA-14
49
UserSt-17
15
DNA-15
50
UserSt-18
16
DNA-16
51
UserSt-19
17
DNA-17
52
UserSt-20
18
DNA-18
53
UserSt-21
19
DNA-19
54
UserSt-22
20
DNA-20
55
UserSt-23
21
DNA-21
56
UserSt-24
22
DNA-22
57
UserSt-25
23
DNA-23
58
UserSt-26
24
DNA-24
59
UserSt-27
25
DNA-25
60
UserSt-28
26
DNA-26
61
UserSt-29
27
DNA-27
62
UserSt-30
28
DNA-28
63
UserSt-31
29
DNA-29
64
UserSt-32
30
DNA-30
65
Dataset Item 1
31
DNA-31
66
Dataset Item 2
32
DNA-32
67
Dataset Item 3
33
UserSt-1
↓
↓
34
UserSt-2
128
Dataset Item 64
Содержание UR Series C70
Страница 2: ......
Страница 10: ...x C70 Capacitor Bank Protection and Control System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 C70 Capacitor Bank Protection and Control System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 124: ...4 30 C70 Capacitor Bank Protection and Control System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 344: ...5 220 C70 Capacitor Bank Protection and Control System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 396: ...8 18 C70 Capacitor Bank Protection and Control System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 414: ...9 18 C70 Capacitor Bank Protection and Control System GE Multilin 9 1 OVERVIEW 9 THEORY OF OPERATION 9 ...
Страница 436: ...10 22 C70 Capacitor Bank Protection and Control System GE Multilin 10 4 SETTING EXAMPLE 10 APPLICATION OF SETTINGS 10 ...
Страница 547: ...GE Multilin C70 Capacitor Bank Protection and Control System B 79 APPENDIX B B 4 MEMORY MAPPING B ...
Страница 548: ...B 80 C70 Capacitor Bank Protection and Control System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Страница 586: ...D 10 C70 Capacitor Bank Protection and Control System GE Multilin D 1 OVERVIEW APPENDIXD D ...
Страница 598: ...E 12 C70 Capacitor Bank Protection and Control System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...