background image

 

TII P/N: 92202701

 

 

 

 

 

 

 

                                                      

 

 

 

 

 

    

                                                                                      

                                                                                             

TII 320 NIZ / TII 126NIZ

                                                      

                                                                                              

TII 325 NIZ / TII 326NIZ 

 141 Rodeo Drive 

Station Protector With Network Interface 

 Edgewood NY 11717 

Rev C 01/08 

Customer Service/Sales  888-844-4720 

 

 

INSTALLATION NOTE

 

 

 

 

 

 

 

 

 

 

 

GENERAL 

a)  This  installation  note  covers  the  description  and 

installation  of  the  TII  325  NIZ,  326  NIZ,  126  NIZ  and 
the  320  NIZ  hereafter  referred  to  as  the  unit.  This 
product  is  designed  to  combine  a  single  pair  TII  325, 
326,  126,  or  320  Station  Protector  with  a  single  pair 
Network Interface Device. 

b)  The  unit  is  furnished  complete  with  a  mounting  base, 

an  RJ-11  interface  jack  and  plug,  customer  wiring 
bridge  ,  retaining  nut,  cover,  and  normally  a  protector 
module  /  angle  driver.  The  unit may also be furnished 
with an optional ringer termination circuit. 

1.  WARRANTY 

a) 

  

  See  TII  Warranty.  If  this  unit  fails  during  the  warranty           

period,  the  factory  should  be  requested  to  authorize 
return.  Return  the  unit  prepaid.  Units  that  fail  due  to 
normal wear or abuse should be discarded. 

2.  DESCRIPTION 

a)    The  unit  is  an  adaptation  of  the  TII  325,  326, and 320 

series  single  pair  Station  Protector.  The  standard 
cover  of  those  products  is  replaced  by  a  cover 
assembly  that  isolates  the  telco  wiring  and  station 
protector  from  the customer. The RJ-11 plug and jack 
are supplied with weather resistant grommets. 

b)    The cover assembly is held in place with a sturdy nylon 

nut.  The  unit  has  a  hinged,  side  opening  cover, 
complete  with  a  provision  for  a  security  seal.  Testing 
instructions are provided inside the cover. 

c)    The  product  is  furnished  complete  and  requires  no 

special tools for installation. 

 

 

3. 

INSTALLATION  WITHOUT STATION ELECTRONICS 

a)  Remove  the  unit  from  the  carton  and  inspect  it 

carefully for damage. If the unit is damaged, obtain 
another. 

b)  Open  the  hinged  door  on  the  face  of  the  unit  and 

unplug the modular plug from the jack (See Figure 
1). 

c)  Remove  the  cover  assembly  from  the  base  by 

loosening  the  nylon  cover  nut  and  then  pulling  the 
cover  assembly  away  from  the  base  (See  Figure 
1). 

d)  To  mount  the  protector  base,  select  the  desired 

hole pattern and knock out the plastic web over the 
holes  with  a  screwdriver.  Position  the  base  to  the 
mounting  surface  and  attach  it  will  appropriate 
hardware. 

e)  Connect  a  proper  station  protector  ground  to  the 

molded-in  ground  stud  using  locally  approved 
grounding methods. 

 

 

 

 

 

 

 

TII 320-71-NIZS 

TII 325-1LM-NIZS 