background image

 

TII P/N: 92202701

 

 

 

 

4.1   STATION PROTECTOR WIRING 

        (If equipped with binding post protection) 

a)  Connect  the  drop  wire  to  the  Tip  and  Ring  of  the 

protector  module,  placing  the  wire  under  the  bottom 
nut  on  each  stud  for  station  protector  module  (See 
Figure 2). 

b)  Turn  the  cover  assembly  over  and  locate  the  spade 

tipped  red  and  green  conductors  that  are  attached  to 
the  modular  jack.  Connect  them  to  the  Ring  and  Tip 
binding posts of the protector module respectively. 

 

 

 

 

 

 

c)  Inspect the ground wire and drop wire connections. 

d)  See 4.2 3 Final Installation Steps 

4.2   STATION PROTECTOR WIRING 

        (If equipped with angle driver) 

4.2.1 Upper Port Subscriber Connections

 

a)  Turn the cover assembly over and Cut spade lugs from 

Red  and  Green  conductors  that  are  attached  to  the 
modular jack. 

b)  Do  not  strip  wire  insulation.    Make  certain  wire  ends 

are cut flush with insulation. 

c)  Unscrew Angle Driver screw to full upright position. 

d)     Fully  insert  the  two wires into their respective Tip and 

Ring (color-coded) ports. 

e)     While  holding  the  two  Customer  side  wires  in  place 

tighten Drive Screw to full down position. 

 

 

 

 

 

 

 

 

4.2.2   Lower Port Telco Connections

 

a)  Do  not  strip  wire  insulation.    Make  certain  wire  ends 

are cut flush with insulation. 

b)  Unscrew Angle Driver screw to full upright position. 

c)     Fully  insert  the  two wires into their respective Tip and 

Ring (color-coded) ports. 

d)     While  holding  the  two  Telco  wires  in  place  tighten 

Drive Screw to full down position. 

e)     See 4.2.3 Final Installation Steps. 

 

 

4.2.3   Final Installation Steps 

a)  Locate  the  yellow  and  black  conductors  also 

attached to the modular jack and insulate them with 
a short piece of tape. Dress them to the side so as 
not  to  interfere  with  the  working  of  the  unit.  (The 
yellow  and  black  wires  may  also  be  terminated  on 
the protector ground post if desired.) 

b)  Carefully  fit  the  cover  assembly  onto  the  base  of 

the  protector, ensuring that no loose ends or other 
wire  pieces  are  protruding  between  the  cover  and 
base. 

c)  Locate  the  ground  stud  with  the  nylon  nut  of  the 

cover  and  screw  it  down  until  the  cover  is  fitted 
snugly to the base. 

d)  Carefully  place  the  station  wire  in  the  lip  of  the 

grommet  and  terminate  the  conductors  on  the 
customer  wiring  bridge.  Inspect  for  shorts  and 
broken wires. 

e)  Insert  the  modular  plug  into  the  modular  jack  and 

close the hinged door. 

4.  INSTALLATION WITH STATION ELECTRONICS 

a) 

Follow steps 4a -4e

 then proceed to next step. 

b)  Terminate  the  Tip-in  and  Ring-in  leads  of  the 

electronics  assembly  onto  the  protector  module 
binding  posts  or  angle  driver  termination,  and 
ground stud if required. 

c)  Take  a  short  piece  of  station wire and connect the 

red  and  green  conductors  respectively  to  the 
Ring-out  and  Tip-out  terminals  of  the  station 
electronics assembly. 

d)  Run  this  wire  to  the  protector  or  angle  driver  and 

dress the end into the protector. Remove a portion 
of  the  jacket  and  prepare  the  red  and  green 
conductors  to  be  spliced  to  the  spade  tipped  red 
and green conductors of the cover assembly of the 
unit. 

e)  Locate the red and green spade tipped conductors 

attached to the modular jack and cut off the spade 
tips. 

f) 

Using  a  Scotch-Loc  or  B  wire  connector,  or  some 
other splicing device, splice the red conductor from 
the Ring-out of the electronics assembly to the red 
conductor  attached  to  the  modular  jack.  Splice the 
green conductor from the Tip-out of the electronics 
assembly  to  the  green  conductor  attached  to  the 
modular jack. 

g)  Dress  all  loops  and  extra  conductors  neatly  inside 

the  protector  and  carefully  fit  the  cover  assembly 
onto  the  base  of  the  protector.  (The  yellow  and 
black wires from the modular jack may be insulated 
and  taped  back,  or  terminated  on  the  protector 
ground post.) 

h)  Complete installation by following steps 4.2.3 (c-e).  

Figure 2 

    Customer Side Cable  

 

    

Telco Side Cable   

 

Telco Side Cable 

Customer Side Cable 

Figure 3 

 

Figure 1 

 

Angle Driver Screw 

Отзывы: