C h a p t e r 1 3 E x pa n s i o n St o r a g e D e v i c e
13.4.1
Backup
The operation procedures for device backup are described below,
1. Monitor AH20MC-5A, AH10PM-5A, or AH15PM-5A by PMSoft, and stop the operation under the
monitoring. Alternatively, set SM072 to 0 to stop O100.
2. Set SR214 by a device monitoring table or by external communication.
Set bit 12~bit 0 in SR214. The values of bit 12~bit 0 in SR124 represents a backup file
name.
To backup, set bit 13 in SR214 to 1.
To backup devices, set bit 15 in SR214 to 1.
For example, if the value in SR214 is A000H, devices will be backed up, the name of the backup file
will be 0, and the file 0.csv can be found in \AHMotion\Device\ in a memory card.
The CSV file embodies the data in the devices. As it includes every device, no individual device is to
be excluded from being backup.
Device parameters can be changed via the CSV file in a general Windows environment. The format
of the CSV file is as shown below.
The first line indicates the format version of the memory cards for an AH500 series motion control
module.
PLC Type: The model name of an AH500 series motion control module
PLC FWVer: Firmware version of a model
1 3 - 5
Содержание AH500
Страница 9: ...viii...
Страница 52: ...Chapter 2 Hardware Specifications and Wiring Wiring AH10PM 5A and a Panasonic CN5 series servo drive 2 31...
Страница 53: ...AH500 Motion Control Module Manual Wiring AH10PM 5A and a Yaskawa servo drive 2 32...
Страница 54: ...Chapter 2 Hardware Specifications and Wiring Wiring AH10PM 5A and a Mitsubishi MJR2 series servo drive 2 33...
Страница 55: ...AH500 Motion Control Module Manual Wiring AH10PM 5A and a Fuji servo drive 2 34...
Страница 115: ...AH500 Motion Control Module Manual 4 16 MEMO...
Страница 375: ...AH500 Motion Control Module Manual 5 260 MEMO...
Страница 376: ...Chapter 6 Data Transmission Table of Contents 6 1 Functions 6 2 6 2 Parameters 6 2 6 3 Usage 6 5 6 1...
Страница 383: ...AH500 Motion Control Module Manual 6 8 MEMO...
Страница 419: ...AH500 Motion Control Module Manual 7 36 MEMO...
Страница 436: ...Chapter 8 Electronic Cam 8 17...
Страница 482: ...Chapter 10 High speed Counters and High speed Timers 3 The cyclic mode is used to measure a frequency 10 7...
Страница 483: ...AH500 Motion Control Module Manual 10 8 MEMO...
Страница 505: ...AH500 Motion Control Module Manual 12 8 MEMO...
Страница 515: ...AH500 Motion Control Module Manual 13 10 MEMO...
Страница 544: ...Appendix A Error Code Table Table of Contents A 1 Error Code Table A 2 A 1...
Страница 547: ...AH500 Motion Control Module Manual A 4 MEMO...