C h a p t e r 1 0 H i g h - s p e e d C o u n t e r s a n d H i g h - s p e e d Ti m e r s
C204: Users can select a mode of counting by setting SM204 and SM205. Input signals are
controlled by X0.10 and X0.11. If SM207 is ON, the function of resetting C204 will be
enabled. Resetting signals are controlled by X0.1.
Reset ti ng C204
Counting pul ses
Counting pul ses
Present value in C204
C204
Pulse
U
A
B
Dir
D
SM205/ SM204: Mode of c ount ing
X0.11
X0.10
SM207=1, X0. 1
C208: Users can select a mode of counting by setting SM208 and SM209. Input signals are
controlled by X0.12 and X0.13. If SM211 is ON, the function of resetting C208 will be
enabled. Resetting signals are controlled by X0.2. C216 counts with C208. It is the first
virtual counter.
Resetti ng C208 (C 216)
Counting pul ses
Counting pul ses
Present value in C208 (C216)
C208(C216)
Pulse
U
A
B
Dir
D
SM209/ SM208: Mode of counting
X0.13
X0.12
SM211=1, X0. 2
C212: Users can select a mode of counting by setting SM212 and SM213. Input signals are
controlled by X0.14 and X0.15. If SM215 is ON, the function of resetting C212 will be
enabled. Resetting signals are controlled by X0.3. C220 counts with C212. It is the second
virtual counter.
Reset ti ng C212 (C 220)
Counting pulses
Counting pulses
Present value in C212 (C220)
C212(C220)
Pulse
U
A
B
Dir
D
SM213/ SM212: Mode of counti ng
X0.15
X0.14
SM215=1, X0. 3
2. If a power cut occurs when a general counter counts, the present value of the counter will be
cleared.
3. If a counter counts up from the present value 2,147,483,647, the next value following
2,147,483,647 will be -2,147,483,648. If a counter counts down from the present value
-2,147,483,648, the next value following -2,147,483,648 will be 2,147,483,647.
1 0 - 3
Содержание AH500
Страница 9: ...viii...
Страница 52: ...Chapter 2 Hardware Specifications and Wiring Wiring AH10PM 5A and a Panasonic CN5 series servo drive 2 31...
Страница 53: ...AH500 Motion Control Module Manual Wiring AH10PM 5A and a Yaskawa servo drive 2 32...
Страница 54: ...Chapter 2 Hardware Specifications and Wiring Wiring AH10PM 5A and a Mitsubishi MJR2 series servo drive 2 33...
Страница 55: ...AH500 Motion Control Module Manual Wiring AH10PM 5A and a Fuji servo drive 2 34...
Страница 115: ...AH500 Motion Control Module Manual 4 16 MEMO...
Страница 375: ...AH500 Motion Control Module Manual 5 260 MEMO...
Страница 376: ...Chapter 6 Data Transmission Table of Contents 6 1 Functions 6 2 6 2 Parameters 6 2 6 3 Usage 6 5 6 1...
Страница 383: ...AH500 Motion Control Module Manual 6 8 MEMO...
Страница 419: ...AH500 Motion Control Module Manual 7 36 MEMO...
Страница 436: ...Chapter 8 Electronic Cam 8 17...
Страница 482: ...Chapter 10 High speed Counters and High speed Timers 3 The cyclic mode is used to measure a frequency 10 7...
Страница 483: ...AH500 Motion Control Module Manual 10 8 MEMO...
Страница 505: ...AH500 Motion Control Module Manual 12 8 MEMO...
Страница 515: ...AH500 Motion Control Module Manual 13 10 MEMO...
Страница 544: ...Appendix A Error Code Table Table of Contents A 1 Error Code Table A 2 A 1...
Страница 547: ...AH500 Motion Control Module Manual A 4 MEMO...