BAT32G1x9 user manual | Chapter 22 CAN control
909 / 1149
Rev.1.02
22.7.17
CAN module last output pointer register (CnLOPT).
The CnLOPT register indicates the number of message buffers to which a data frame or remote frame
was last transmitted.
Figure 22-42. CAN
module last outputs pointer register format
(CnLOPT
).
LOPT7-LOPT0
Send History List Last Output Pointer (LOPT
).
0 to
15
When the CnLOPT register is read, the contents of the element indexed by the last out
pointer (LOPT) of the received history list are read. These indicate the number of
message buffers to which the data frame or remote frame was last transmitted
Note: If a data frame or remote frame is never transmitted from the packet buffer, the
value read from the CnLOPT register is undefined. If the THPM bit is set to 1
after the CAN module changes from initialization mode to operating mode, the
read value of the CnLOPT register is undefined.