![Cmsemicon BAT32G1 9 Series Скачать руководство пользователя страница 911](http://html1.mh-extra.com/html/cmsemicon/bat32g1-9-series/bat32g1-9-series_user-manual_2627609911.webp)
BAT32G1x9 user manual | Chapter 22 CAN control
911 / 1149
Rev.1.02
22.7.19
CAN Module Timestamp Register (CnTS).
CnTS registers are used to control the timestamp function
Figure22-44. CAN
Module Timestamp Register Format
(CnTS) (1/2).
(a) read
(b) write
Note: When the CAN module is in normal operating mode with ABT, the lock
function of the timestamp function must not be used.
(a)
read
TSLOCK
Timestamp lock function enables bits
0
The timestamp lock feature stops
Each time the selected timestamp capture event occurs, the TSOUT signal is toggled
1
The timestamp lock feature enables
Each time the selected timestamp capture event occurs, the TSOUT signal is toggled.
However, when the data frame is correctly received packet buffer 0, the TSOUT
output signal is locked
1
1 TSEN bit is automatically cleared to 0