10.8.3.5
Outputs force-cut source checkout and unchecked out states
Whether the output forced cutoff source is checked out is selected by the cutoff source bit (OPCTL0.
IN_SEL1,OPCTL0. IN_SEL0) The level of the selected signal (INTP0, CMP0) is determined.
If you set OPCTL0. the IN_EG
is 0, the high level is the
source detected state, and the low level is the undetected
state.
If you set OPCTL0. the IN_EG
is 1, the low level is the
source detected state, and the high level is the undetected
state.
Note: Before selecting the INTP0 input by setting the IN_SEL1, IN_SEL0, comparator 0 output as the forced
cutoff factor, if the output force cutoff source is outside the threshold range, the IN_SEL1 and IN_ When SEL0 is
set, HZIF0 bit is set to 1, while HZOF0 and HZOF1 are not set.