BAT32G1x9 user manual | Chapter 22 CAN control
843 / 1149
Rev.1.02
(5) Remote frames
The remote frame consists of 6 bits of field master
Figure 22-4. Remote frames
Remote frames
R
D
Inter-frame space
End of Frame (EOF)
ACK field
CRC field
Control the field
Arbitration
Venue
Frame Start
(SOF
).
Note 1 Even if the data length of the control farm is not "0000B", the data farm will not send
2. D: Dominant = 0
R: Recessive
= 1
(6) Bit field description
< 1> Frame Start
(SOF
).
The frame start field is at the beginning of a data frame or remote frame
Figure 22-5. Frame Start (SOF).
Note D: Dominant
= 0
R: Recessive = 1
•
If a dominant bit is detected in the bus idle state, a hard synchronization is performed (the current TQ is
designated as the SYNC segment)
•
If a dominant bit is sampled at a sample point after such a hard synchronization, the bit is assigned as
SOF. If a recessive bit is detected, the protocol layer returns to the bus idle state and treats the preceding
dominant pulse as interference-only. In this scenario, no error frame is generated.
<1>
<2>
<3>
<5>
<6><7>
<8>
Frame start
(Arbitration Venue).
(interframe space or bus idle)
R
D
1 bit