BAT32G1x9 user manual | Chapter 22 CAN control
849 / 1149
Rev.1.02
22.2.4
Error frame
If an error is detected, an error frame is sent at the next node.
Figure 22-15: error frame
(6 bits)
(8 bits)
(1 to 6
bits)
error
frame
Frame interval or
overflow frame
error flag 2
error identifer
error flag 1
error bit
Note D: Dominant = 0
R: Recessive = 1
Table22-7: Error Frame Definition
No.
name
Number of digits
definition
<1>
Error flag 1
6
Active error node: Continuous output of 6 dominant bits
Passive Error Node: Continuous output of 6 recessive bits
When one node is outputting a passive error flag and another node
outputs an explicit bit, the passive error flag is not cleared until six
consecutive bits of the same polarity are detected.
<2>
Error flag 2
0~6
The node accepts error flag 1 detection bit fill error and then
issues this error flag.
<3>
Error delimiter
8
Continuous output of 8 recessive bits.
If an dominant bit is detected in the 8th bit, the next bit
emits an overload frame
<4>
Error bit
–
Error detected
An error flag is issued immediately after the error bit. .
If it is a CRC error, the error bit is issued after the ACK delimiter
<5>
Inter-frame
space/overload frames
–
An inter-frame space or overload frame is emitted at this time