434 / 1149
Rev.1.02
10.8.3.6
Timing plot of the counter of timer M reaches 0000H
When the hardware releases the output force cutoff, the force cutoff condition varies depending on the
action mode of timer M.
(
1
)
Timer M works in the time series of 0000H when the output comparison function is reached
⚫
Count value = 0000H, timer M count starts: forced cutoff cannot be lifted
⚫
Timer M in the counting, using software to assign the countera value of 0 000H, to remove the
forced cutoff state
⚫
The timer overflows, the count value becomes 0000H, and the forced cutoff state is lifted
⚫
In line with the value of TMGRA0, the count value becomes 0000H, and the forced cutoff state
is lifted
(
2
)
Timer M works in the PWM function when the count value reaches the timing of 0 000H
⚫
Count value = 0000H, timer M count starts: forced cutoff cannot be lifted
⚫
Timer M in the counting, using software to assign the countera value of 0 000H, to remove the
forced cutoff state
⚫
In line with the value of TMGRA0, the count value becomes 0000H, and the forced cutoff state
is lifted
(
3
)
Timer M works in reset synchronous PWM mode when the count value reaches the timing of 0 000H
⚫
Count value = 0000H, timer M count starts: forced cutoff cannot be lifted
⚫
Timer M in the counting, using software to assign the countera value of 0 000H, to remove the
forced cutoff state
⚫
In line with the value of TMGRA0, the count value becomes 0000H, and the forced cutoff state
is lifted
(
4
)
Timer M works in PWM3 mode when the count value reaches the timing of 0 000H
⚫
Count value = 0000H, timer M count starts: forced cutoff cannot be lifted
⚫
Timer M in the counting, using software to assign the countera value of 0 000H, to remove the
forced cutoff state
⚫
In line with the value of TMGRA0, the count value becomes 0000H, and the forced cutoff state
is lifted
(
5
)
When the timer M count value reaches 0000H and timer M stops working
If the timer M stops working while the count value reaches0 000H, the forced cutoff cannot be lifted.
Fig. 10-90 timing sequence when counting value = 0000H
(Count source = Fclk/2, the counter stops when the timer M count value reaches0 000H).
PWMOP operational
clock
TIMER M counter0
TMSTR.TSTART0
detection signal when
TIMER M count = 0000H