BAT32G1x9 user manual | Chapter 22 CAN control
949 / 1149
Rev.1.02
Note: The timestamp function using the TSLOCK bit stops switching the TSOUT bit by receiving
a data frame in packet buffer 0. Therefore, message buffer 0 must be set to receive packet
buffer. Because the receive packet buffer cannot receive remote frames, it is not possible
to stop switching the TSOUT bit by receiving remote frames. When a data frame is
received in a packet buffer other than the message buffer (packet buffer 0), the switching
of the TSOUT bit does not stop. For these reasons, when the CAN module is in normal
mode of operation with ABT, it is impossible to receive data frames in message buffer 0
because message buffer 0 must be set to send message buffer. Therefore, in this mode of
operation, the TSLOCK bit cannot be used to stop the function of toggling the TSOUT bit.
By switching the input source (using TMOS1), the capture trigger signal (TSOUT of CAN controller
channel 0) can be input to channel 2 of timer array unit 0 without having to externally connect the TSOUT of
CAN controller channel 0 and TI02.
Figure 22-60. the switch of the input sources
CAN controller channel 0
selector
1: CAN controller channel 0 selection TSOUT
0: TI02 selection
TI02 input
Note 1
TIOS10: Bit 0 of time input selection register TIOS1 (see Chapter 6 General Purpose Timer Units).
2. Available pins vary by product. For more information, see Chapter 2 Pin Functions