BAT32G1x9 user manual | Chapter 10 Timer M
437 / 1149
Rev.1.02
10.8.4
Precautions
(1) When the pulse output forced cutoff of timer M works at the same time as the output force cutoff of PWMOP, the
priority is as follows:
Table 10-22 Priority at the time of enforcement deadline
Pin status at PWMOP forced cutoff
forbid
Hi-Z
L level
H level
Pin state when
timer M forces
off
forbid
forbid
Hi-Z
L level
H level
Hi-Z
Hi-Z
Hi-Z
L level
H level
L level
L level
Hi-Z
L level
H level
H level
H level
Hi-Z
L level
H level
(2) In the complementary PWM mode, if the PWMOP is in the output forced cut-off state, the timer M also enters the
pulse output forced cut-off state, which may produce an edge of the de-cut off for the PWMOP.
(3) When using EVENTC as the cutoff source, you must use software to deactivate the cutoff state (HS_SEL=1).
(4) When using the output cut-off hazard countermeasure, the output of the timer M via PWMOP is delayed by one
clock cycle.
(5) When using the output cut-off hazard countermeasure, the multiplexing function and the PORT function can be
switched between the timer count operation through the output pin of the timer M of the PWMOP.
(6) Select the effective width of the comparator 0 output and the INTP0 input must be greater than one clock cycle.