BAT32G1x9 user manual | Chapter 19 Universal serial communication unit
602 / 1149
Rev.1.02
(2) Procedure
Figure 19-23
The initial setup steps of the master transmission
initial configuration starts
configure PER0 register
configure SPSm register
configure SMRmn register
configure SCRmn register
configure SDRmn register
configure SOm register
Modifing SOEm register
configuration
configure port
write SSm register
initial configuration completes
release universal serial
communication unit from reset state,
start providing clock.
configure operational clock
configure operational mode..etc.
configure communication format
configure transmit baud rate
(configure operationl clock(fMCK)
scaled transmission clock)
configure serial clock (CKOmn) and
serial data(SOmn) initial output
voltage
set SOEmn bit to 1, allow target
channel data output
configure port register and port mode
register (target channel data output
and clock output are valid)
set SSmn bit of target channel to 1
(Semn=1: set as operation enable
state)
complete initial configuration.
If transmit data to SIOp register (bit
7~0 of SDRmn register), then
communcation starts.
Figure 19-24
The abort step of the master transmission
termination configuration
starts
TSFmn = 0
?
write into STm register
modify SOEm register
configuration
modify SOm register
configuration
configure PER0 register
termination configuration
ends.
(selection)
(mandatory)
(mandatory)
(selection)
(selection)
Yes
No
if there are ongoing data transmission,
then wait till transmission completed. (if
need urgent stop, then no need to wait).
set STmm bit of target channel to 1.
(SEmn=0: set to operation stop state).
set SOEmn bit to 0, stop output of target
channel
while emergency stop, based on needs,
modify serial clock (CKOmn) and serial
data(Somn) voltage of target channel.
when using deep sleep mode, stop clock of
universal serial communication unit, configure
to reset state.
finish termination configuration, enter into
next processing.