BAT32G1x9 user manual | Chapter 10 Timer M
353 / 1149
Rev.1.02
Figure 10-32 Format of the timer M counter i(TMi) (i=0, 1) [Complementary PWM Mode ( TM0) ]
Address: 0x40042A76
(TM0),
0x40042A86
(TM1) after reset:
0000H R/W
Symbol 15 14 13 12 11
10 9 8 7 6 5 4 3 2 1 0
TMi
—
function
Configure range
bit15
~
0
The dead time must be set.
Increment or decrement counts on the
count source.
If an overflow occurs, the OVF bit of the TMSR0 register becomes
"1".
0001H~FFFFH
Figure 10-33 Format of the timer M counter i(TMi) (i=0, 1) [Complementary PWM Mode ( TM1) ]
Address: 0x40042A76
(TM0),
0x40042A86
(TM1) after reset:
0000H R/W
Symbol 15 14 13 12 11
10 9 8 7 6 5 4 3 2 1 0
TMi
—
function
Configure range
bit15
~
0
Must be set to "0000H". Increment or
decrement counts on the count
source.
If an overflow occurs, the UDF bit of the TMSR1 register becomes
"1".
0000H~FFFFH