BAT32G1x9 user manual | Chapter 15 A/D converter
496 / 1149
Rev.1.02
Note 1
If you select the internal reference voltage (1.45V) as the reference voltage for comparator
0
or comparator
1, the
temperature sensor output cannot be selected.
○4-channel scan mode (ADM1. ADMD=1)
ADISS
ADS4
ADS3
ADS2
ADS1
ADS0
Analog input channel
Scan 0
Scan 1
Scan 2
Scan 3
0
0
0
0
0
0
ANI0
ANI1
ANI2
ANI3
0
0
0
0
0
1
ANI1
ANI2
ANI3
ANI4
0
0
0
0
1
0
ANI2
ANI3
ANI4
ANI5
0
0
0
0
1
1
ANI3
ANI4
ANI5
ANI6
0
0
0
1
0
0
ANI4
ANI5
ANI6
ANI7
0
0
0
1
0
1
ANI5
ANI6
ANI7
ANI8
0
0
0
1
1
0
ANI6
ANI7
ANI8
ANI9
0
0
0
1
1
1
ANI7
ANI8
ANI9
ANI10
0
0
1
0
0
0
ANI8
ANI9
ANI10
ANI11
0
0
1
0
0
1
ANI9
ANI10
ANI11
ANI12
0
0
1
0
1
0
ANI10
ANI11
ANI12
ANI13
0
0
1
0
1
1
ANI11
ANI12
ANI13
ANI14
0
0
1
1
0
0
ANI12
ANI13
ANI14
ANI15
Other than the above
Prohibit settings.
○3 channel scan mode (ADM1. ADMD=1)
ADISS
ADS[4:0]
Analog input channel
Scan 0
Scan 1
Scan 2
1'b0
5'h00
ANI0
ANI1
ANI2
1'b0
5'h01
ANI1
ANI2
ANI3
1'b0
5'h02
ANI2
ANI3
ANI4
1'b0
5'h03
ANI3
ANI4
ANI5
1'b0
5'h04
ANI4
ANI5
ANI6
1'b0
5'h05
ANI5
ANI6
ANI7
1'b0
5'h06
ANI6
ANI7
ANI8
1'b0
5'h07
ANI7
ANI8
ANI9
1'b0
5'h08
ANI8
ANI9
ANI10
1'b0
5'h09
ANI9
ANI10
ANI11
1'b0
5'h0A
ANI10
ANI11
ANI12
1'b0
5'h0B
ANI11
ANI12
ANI13
1'b0
5'h0C
ANI12
ANI13
ANI14
1'b0
5'h0D
ANI13
ANI14
ANI15
Other than the above
Prohibit settings.