Fig. 10-86 Example of software release cutoff (timer M, 1 channel count
).
PWMOP operational
clock
TMSTR.TSTART0
TMSTR.TSTART1
valid signal when
count of TM0 is
0000H.
valid signal when
count of TM1 is
0000H.
input edge selection
IN_EG=0
comparator0 output
HZIF0
HZOF0
HZOF1
Forced cut-off release
control HZ_REL
Forced cut-off release
mode selection HS_SEL=1
Force cutoff source
selection
IN_SEL1=0,INSEL0=1
TMIOA0 output
from PWMOP
TMIOA1 output
from PWMOP
(1) When the rising edge of the comparator 0 output signal is detected, the output of the TMIOA0, TMIOA1
pin is forced to cut off.
(2) Set HZ_REL to 1 and wait for each count count value to change to 0000H.
(3) When the count value of TM0 reaches 0 000H, the forced cutoff state of T MIOA0 is lifted.
(4) After the force cutoff is lifted, HZ_REL bit becomes 0.
For detailed timing of the mandatory cutoff, refer to Figure 10-75.
For the detailed timing of the forced cut-off, refer to Fig. 10-76, Fig. 10-77.
For HZ_REL the timing of automatic zeroing, refer to FIG. 10-84.