![Cmsemicon BAT32G1 9 Series Скачать руководство пользователя страница 417](http://html1.mh-extra.com/html/cmsemicon/bat32g1-9-series/bat32g1-9-series_user-manual_2627609417.webp)
BAT32G1x9 user manual | Chapter 10 Timer M
417 / 1149
Rev.1.02
Figure 10
–74
Example of output force cutoff/hardware de-output force cutoff
(Example of TMIOB0, TMIOC0, TMIOD0
pin being forced to cut off
).
PWMOP operational
clock
valid timing signal
when TM0 counter at
0000H.
force release mode
selection HS_SEL=0
force cut-off sourse
selection
IN_SEL1=0
,
IN_SEL0=1
input edge selection
IN_EG=0
comparator0 output
HZIF0
TMIOB0 output
TMIOC0 output
TMIOD0 output
HZOF0
(
1
)
When the rising edge of the comparator output signal is detected, the TMIOB0,
TMIOC0, TMIOD0 pin
outputs are forced
to cut off.
(
2
)
After the falling edge of the comparator output signal is detected, theHZIF0 bit
is cleared.
(
3
)
At a TDi