Figure 21-12 The abort step of the master receive
Note: n=0,1
Start of abort
setting i
End i of the abort
setting
SPTFn=0?
No
Yes
Set the PER2
register
If there is data being transferred, wait
for the transfer to end
Place the SPIEn at the position "0" to
stop the operation of the SPI
To use deep sleep mode, stop the
clock of the SPI unit and set the
reset state
Note 1
Write the SPIMn
register
Note 1: In receive-only mode, the SPI transmission is triggered by reading the value of
the SDRIn register. If the SPI is not aborted in time, there may be a redundant
transmission after the last read of SDRIn.
If you want to avoid the last redundant transmission, you can turn off SPIE N after waiting
for an SCK cycle after the penultimate data readout. The transfer of the SPI will be
aborted after the last data transfer is complete.
The penultimate (m-