BAT32G1x9 user manual | Chapter 10 Timer M
325 / 1149
Rev.1.02
Figure 10-11 : Format of the output control register (TMOCR) of the timer M [PWM function].
Address: 0x40042A69
after reset:
00H R/W
symbol
TMOCR
TOD1
TMIOD1 Initial Output Level Selection
Note
1
0
The initial output is an invalid level.
1
The initial output is the effective level.
TOC1
TMIOC1 Initial Output Level Selection
Note
1
0
The initial output is an invalid level.
1
The initial output is the effective level.
TOB1
TMIOB1 Initial Output Level Selection
Note
1
0
The initial output is an invalid level.
1
The initial output is the effective level.
TOA1
Selection of the initial output level of TMIOA1
must set to "0".
TOD0
Select
Note
1
for the initial output level of TMIOD0
0
The initial output is an invalid level.
1
The initial output is the effective level.
TOC0
TMIOC0 Initial Output Level Selection
Note
1
0
The initial output is an invalid level.
1
The initial output is the effective level.
Valid in reset synchronous PWM
mode and complementary
PWM
mode.
TOB0
TMIOB0 Initial Output Level Selection
Note
1
0
The initial output is an invalid level.
1
The initial output is the effective level.
TOA0
Selection of the initial output level of TMIOA0
must set to "0".
Note
1
When
the
TMOCR
register is set when the pin function of the
TMOCR
register is a waveform output
, the
initial output level is output.
7
6
5
4
3
2 1
0
TOD1
TOC1
TOB1
TOA1
TOD0
TOC0
TOB0
TOA0