BAT32G1x9 user manual | Chapter 10 Timer M
430 / 1149
Rev.1.02
(
b
)
Timer M operates in reset synchronous PWM mode
Set the HZ_REL to 1, and at a T M0 count value of 00 000H, the output force cutoff of all T MIO pins is
removed.
Figure 10-87 Example of software release forced cutoff
PWMOP operational
clock
TMSTR.TSTART0
TMSTR.TSTART1
HZIF0
TMIOB0 output
from PWMOP
TMIOA1 output
from PWMOP
HZOF0
HZOF1
valid signal when count
of TM0 is 0000H.
valid signal when count
of TM1 is 0000H.
Forced cut-off release
control HZ_REL
Forced cut-off release
mode selection HS_SEL=1
Force cutoff source
selection
IN_SEL1=0,INSEL0=1
input edge selection
IN_EG=0
comparator0 output
(1) When the rising edge of the comparator 0 output signal is detected, the output of the TMIOA0, TMIOA1
pin is forced to cut off.
(2) Set HZ_REL to 1 and wait for channel 0count count value of timer M to change to 0000H.
(3) When the count value of TM0 reaches 0000H, the forced cut-off state of T MIOB0 and TMIOA1 is lifted
(the action of channel 1 is not affected).
(4) After the force cutoff is lifted, HZ_REL bit becomes 0.
For detailed timing of the mandatory cutoff, refer to Figure 10-75.
For the detailed timing of the forced cut-off, refer to Fig. 10-76, Fig. 10-77.
For HZ_REL the timing of automatic zeroing, refer to FIG. 10-84.