BAT32G1x9 user manual | Chapter 31 Voltage detection circuit
1106 / 1149
Rev.1.02
Note 1
After generating a reset signal, the LVIMK flag changes to "1".
2. When using interrupt &reset mode, it must be set according to the "Setting Steps for Confirmation/Reset of the
Working Voltage of Figure 30-7" after the interruption occurs.
3. When using interrupt & reset mode, it must be set according to "Figure 30-8 Initial Setup Steps of Interrupt &
Reset Mode" after de-resetting.
Note V
POR
:
The POR
supply voltage rises to the detection voltage
V
PDR
:
POR
supply voltage drop sense voltage
Figure 30-7
The setup steps for confirming/resetting the operating voltage
set LVILV bit to "0", configure high voltage detection
voltage level (VLVDH)
INTLVI occurs
push stack operation
LVISEN = 1
LVILV = 0
LVISEN = 0
LVIOMSK= 0
LVD reset occurs
LVISEN = 1
LVIMD = 0
LVISEN = 0
normal operation
generate LVD internal reset
Yes
No
No
perform necessary push stack operation
set LVISEN bit to "1",mask voltage
detection(LVIOMSK=1).
set LVISEN bit to "0", enable voltage detection
set LVISEN bit to "1",mask voltage
detection(LVIOMSK=1).
set LVIMD bit to "0", configure interrupt mode
set LVISEN bit to "0", enable voltage detection
when LVD circuit did not generate internal reset, it
tells the voltage has recovered to level
VDD
VLVDH