BAT32G1x9 user manual | Chapter 10 Timer M
432 / 1149
Rev.1.02
10.8.3.4
Hazard countermeasures
If the TMIO pin switches between the multiplexing function and the PORT function in the forced cut-off
state/forced cut-off state/timer M action, there is a risk of malfunction. The H AZAD_SET can be set to 1 to allow
hazard countermeasures to avoid this risk.
Note that when using hazard countermeasures, the output of timer M is delayed by a clock cycle than when the
hazard countermeasure is disabled.
Figure 10-89
Hazard countermeasure timing diagram
PWMOP operational
clock
force cut-off hazard
control selection
HAZAD_SEL=1
Before TMIOji output
Hazard countmeasure
After TMIOji output
Hazard countmeasure
represents cut-off state (value fixed at H, L or Hi-Z
accordiing to register configuration)
Note: j=A,B,C,D
;
i=0,1