1

A

B

I

E

D

C

F

G

H

RC-4Bi
RC-7Bi

RC-1260Bi

Instruction

Manual

RC-7BI MODEL SHOWN

(The RC-4Bi has a 20-minute pause position between station #4 and "REST.")

DESCRIPTION OF CONTROLS

    

Refer

 to 

Figure 1

A. HOUR DIAL with 23 CYCLE START PINS:

  The HOUR dial contains 23 pins for

scheduling automatic "Starts" on any hour (except midnight—which is day changeover
time). Embossed characters provide quick identification for each hour, AM or PM,
noon and midnight. Captive type pins are designed for simple push-pull operation.

B. DAY DIAL with 14 SCHEDULING PINS:  

The calendar DAY dial contains 14 cap-

tive pins for scheduling irrigation everyday or any day within a two week range. Each
pin represents a 24 hour period beginning at midnight. Embossed characters are on
the dial, adjacent to each day of the week.

C. STATION SELECTOR/INDICATOR DIAL:

  The STATION selector/indicator dial

contains the timing controls (D) for each of the stations. The dial automatically rotates
during a watering cycle with the current station appearing at the top, under the station
pointer. REST indicates the system is off and no watering is taking place. The dial is
also used for manual selection of any station for semi-automatic operation.

Figure 1

Содержание RC-4Bi

Страница 1: ...tion B DAY DIAL with 14 SCHEDULING PINS The calendar DAY dial contains 14 cap tive pins for scheduling irrigation everyday or any day within a two week range Each pin represents a 24 hour period beginning at midnight Embossed characters are on the dial adjacent to each day of the week C STATION SELECTOR INDICATOR DIAL The STATION selector indicator dial contains the timing controls D for each of t...

Страница 2: ...s position eliminates controller output to the system valves without interrupting the clock operation F FUSE 1 5 AMP Slow Blow fuse protects the controller from damage due to cur rent overload Replace fuse after the source of trouble has been remedied G CURRENT STATION INDICATOR STATION indicator identifies the current posi tion of controller operation See control C H CURRENT TIME INDICATOR TIME i...

Страница 3: ...ation 1 Brown 2 Red 3 Orange 4 Yellow 5 Green 6 Blue 7 Violet 8 Gray 9 White 10 White Blk 11 White Bm 12 White Red Master Valve Wht Orn Valve Common White 2 Transformer Wht Red Wht Red w line input label Wht Brn w line input label Figure 3 MOUNTING 1 Choose a location that provides a minimum clearance of 13 wide x 8 high Since the electrical connections are provided at the bottom of the cabinet cl...

Страница 4: ...Make sure transformer is plugged into a wall receptacle 5 Adjust each station TIME control to the 5 minute mark See Figure 6 6 Rotate the STATION dial counterclockwise to position Station 1 under the pointer Watering should commence shortly as the automatic mechanism latches with the Sta tion dial The 5 minute interval should provide sufficient time to observe control valve operation If more time ...

Страница 5: ...ointer This completes the controller clock setting SCHEDULING AUTOMATIC OPERATION Make sure the HOUR and DAY dials are set to the correct time and that all pins are in the out position 1 Push in the pin s corresponding to the day s on which watering is desired Re member each DAY pin represents a 24 hour period beginning at midnight 2 Next select the desired starting time s and push in the correspo...

Страница 6: ...rclockwise to position the desired station at the top just ahead of the Station pointer Allow the automatic mechanism to advance into the de sired timing zone The selected station will operate for the time set on the dial after which the remaining stations will follow in sequence until the REST position again ap pears under the Station pointer RAIN SHUTDOWN There may be occasions where it is desir...

Страница 7: ...s do not op erate a Station time set at OFF b Faulty valve wiring a Set TIME control for more than 3 minutes b Check connections be tween controller and valves Also check valve actuators Station dial does not stop at a Timed station a Insufficient time set on dial a Adjust the TIME control for more than 3 minutes Should trouble be isolated in the controller mechanism remove the entire panel as sem...