6.
Sometimes it is desirable to disable a
command temporarily, without losing its
settings.
This can be accomplished by pressing the
Disable
button, as shown on the right.
Disabled commands are shown in the table
with leading minus signs
‘-’.
When a
command is disabled you may still have the
option to test the command. To reactivate the
settings, click on the
Enable
button.
7.
Buttons are also provided for permanently
clearing a table entry
Clear
and clearing all
table entries
Clear All
. Note these functions
are not undoable. Information will be lost
when the buttons are selected.
7.16.4 Audio-Follow Operation
Once set up, operation is completely automatic. Whenever a source goes on or off
Program, the appropriate command (or commands) is (are) sent. On the control panel
and the Multi-View, when sources tally red they are on program and the commands are
triggered. The Audio Follow setup window can be closed, but commands will continue
to be sent.
In addition, some Audio Mixers, like the Yamaha O1V, can send VU Audio Meters back
to the Multi-View to be displayed. This VU Meters can also active some of the
programming features of the full Audio Follow menu.