Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
228
report coldplate
temperature
Reports the coldplate temperature in degrees
Celsius. You can send either 0 or 1 data bytes.
If you send 0 data bytes, the unit reports the
coldplate temperature in degrees Celsius.
If you send 1 data byte, the unit reports the
coldplate temperature in tenths of degrees
Celsius.
Send 1 data byte:
• 0 = Coldplate temperature
• 1 = Reserved
Returns 2 data bytes representing the
requested data.
0 or 1
2
231
report unit serial or
part number
If you send 0 data bytes, reports the unit serial
number; if you send 1 data byte, you can
request either the unit serial number or the
unit part number.
Send 0 data bytes:
• Returns 4 data bytes (32-bit value)
representing the unit serial number.
Send 1 data byte:
• Byte 0 = Value to be returned.
◦ 0 = Requests unit serial number
◦ 1 = Requests unit part number
Returns as many as 12 ASCII characters
representing the unit part number (315 ...) or
the unit serial number.
0 or 1
4, or as
many as 12
244
report diagnostic
status
Reports the results of the diagnostic self test.
Send 1 data byte.
• Byte 0 (8-bit value)
◦ 1 = Report diagnostic status
For the diagnostic status report, returns 5 data
bytes.
• Byte 0 = Status code
1
5
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑58
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...