Table 3‑2. Electrical specifications (Continued)
Description
Specification
Diagnostics
The generator will evaluate its internal parameters for the relative
health of the generator. Special diagnostic capability is provided for
testing into short (0 Ω) load.
Tuning Algorithm
The unit is designed and programmed to utilize a sweep frequency algorithm to optimize power
delivery and minimize load mismatch as detected by the unit's output sensor. The algorithm is
able to:
• Minimize load mismatch
• Lock the generator at a tune point
• Track (re-tune) frequency to follow changes in load impedance to minimize load mismatch
Frequency tuning range
360.1 kHz to 439.6 kHz
Frequency preset: Start
minimum and maximum
frequency
360.1 kHz to 439.6 kHz, 1 kHz resolution
Tune time
< 0.1 second from RF enabled at a preset frequency (within 10% or
2 W of the minimum reflected power, whichever is greater)
Typical tune time for
factory set tuning
parameters
60 ms tuning delay +25 ms tuning
Tracking and re-tune
< 0.1 s maximum
If load mismatch increases above a user defined threshold, the
generator will re-tune.
Tuned frequency
repeatability
± 2 kHz
Pulsing into Broadband 50 Ω
Frequency range
10 Hz to 2 kHz (minimum on width has to be satisfied)
Duty cycle range
10% to 90% (minimum on width has to be satisfied)
Minimum on width
225 μs
Rise/ fall time
When output voltage reaches 67% of nominal:
• Rise time 10 μs maximum
• Fall time 10 μs maximum
Settling time
When output voltage settles within 10% of nominal:
• 300 μs at 5 W output power
• 30 μs at 2000 W output power
Voltage overshoot
With a 50 Ω broadband load:
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Specifications
3‑7
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...