Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
◦ 2 = Delivered power limit
If you selected SOA mode
◦ 0 = Disabled
◦ 1 = Enabled
If you selected memory mode:
◦ 0 = Volatile
◦ 1 = Nonvolatile
Command
248
reports this value; B0 = 50.
118
set fixed frequency
memory mode
(subcommand 51)
Sets the fixed frequency mode to either
volatile or nonvolatile.
• When set to volatile, the fixed frequency
defaults to the center frequency on power
up.
• When set to nonvolatile, the fixed
frequency defaults to the factory default
fixed frequency setting or last setting if
changed from the factory default. See
product specification for the fixed
frequency factory default setting.
The factory default setting for this command
is configured for each product option. See the
product specification for the default setting.
Send 4 data bytes.
• Bytes 0 and 1 = 51 (set fixed frequency
memory mode)
• Bytes 4 and 5 = Mode setting
◦ 0 = Volatile
◦ 1 = Nonvolatile
Command
248
reports this value; B0 = 51.
4
1
128
report power supply
type
Reports the power supply type.
You can send 0 or 1 data bytes.
Send 0 data bytes:
0 or 1
9 or 10
ASCII
characters
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑38
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...