1. Configure the unit as a master using the serial communications port command
26
, subcommand 1.
2. To enable pulsing, send a valid set of frequency and duty cycle settings to the
Paramount MF 2 kW generator:
◦ Command
93
– pulsing frequency
◦ Command
96
– duty cycle.
3. To disable pulsing, send a value of zero to either the pulsing frequency
command or the duty cycle command.
Serial communications port commands
193
and
196
report the frequency and duty
cycle settings. Serial communications port command
172
reports the slave input
delay setting.
The unit does not save pulsing settings when you turn it off. To return pulsing
settings to default, cycle power to the unit.
If using master/ slave, you do not need to make identical pulsing settings for all units.
SAFE OPERATING AREA (SOA) FEATURE
When enabled, the safe operating area (SOA) feature limits delivered power in
different operating areas based on frequency and Γ. A hardware-controlled loop uses
a lookup table to limit (that is, to foldback) power output to prevent exceeding
programmed limits. This lookup table is stored in flash memory independent of
firmware. The programmed limits in the lookup table are created to specific customer
requirements.
When the SOA feature limits power, the unit sets the protection limit bit and the
warning present bit in the process status. AE Bus commands
162
or
219
read the
process status. The SOA protection warning code
74
is also set. The SOA protection
warning and the process status bits self clear when no longer operating in limiting
conditions.
The SOA feature is enabled/disabled using AE Bus command 118 (subcommand 50).
This feature is not available in all options. See product specification for details.
MAINTENANCE
Consumable Parts
Some parts in the Paramount MF 2 kW are consumable and may wear out over time.
For a current list of consumable and wear components in the Paramount MF 2 kW as
well as for estimated lifetimes and recommended refurbishment schedules, please
contact AE Global Services.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Installation, Setup, and Operation
5‑29
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...