FIRST TIME OPERATION
Minimum Operating Requirements
The Paramount MF 2 kW generator provides serial and user communications
interfaces. The
User
port provides only essential control capabilities. The RS-232
interface provides full control and read back capabilities. When the unit is operated
through the
User
port, the RS-232 interface can be used to read back unit parameters.
Whether you control and monitor the unit through the
User
port or the RS-232
Host
interface, you must satisfy the
User
port
INTERLOCK
(pins 10 and 23) signal to
operate the Paramount MF 2 kW generator. The RF output cable interlock must also
be satisfied by firmly connecting the RF cable.
If the unit is operated through the RS-232
Host
interface, positive voltage between
4 V and 24 V should be supplied to pins 4 (positive) and 17 (return) of the
User
port
(the
RF POWER ON
signal).
For RF delivery, set point in power control mode should be set between the minimum
and maximum specifications. For RF delivery in voltage control mode, set point
should be set at 20 V or more.
To Operate the Unit for the First Time
1. Install the generator according to the installation procedures in this user manual.
2. Turn on the circuit breaker supplying AC input power to the generator.
3. Turn on the circuit breaker at the rear of the generator. The front panel numeric
display should light.
4. Connect the RF cable to the output connector and make sure cable is connected
all the way.
If the RF cable is not fully connected, the RF output cable interlock may not
engage.
5. Establish interlock connection through the generator
User
port.
The
INTERLOCK
LED should light. This LED will only light if both the RF
cable and
User
interlocks are satisfied.
6. Set the generator to operate in any of the available serial or user
communications interfaces.
The generator returns to user control mode every time that AC power is cycled.
To change the control mode, use host command
14
.
7. If in the host control mode, make sure that a positive voltage between 4 V and
24 V is supplied to pins 4 (positive) and 17 (return) (
RF POWER ON
) of the
User
port.
See the
User
port
RF POWER ON
signal for more information.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Installation, Setup, and Operation
5‑19
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...