Table 3‑2. Electrical specifications (Continued)
Description
Specification
Asynchronous
voltage sample
RF pulse
Sampling window
(150 usec
deadtime)
Valid Sample
Window
Valid Sample
Window
3800
Figure 3‑1. Timing diagram
External Voltage Control Mode
General specification
When operating the unit in external voltage regulation mode:
• Minimum voltage setpoint in this mode = 0.1 V
• Maximum forward power in the voltage control mode = 1800
W
Control loop response
time
Typical settling time is 8 μs to 10 μs when operating on 50 Ω load
with peak detector from the AE Low Frequency Fixed Match.
Settling time is measured from the start of step disturbance to 90%
change of the output voltage.
Sense Voltage In
input
characteristics
Input specification for this SMA connector:
• Input voltage 0 V to 10 V
• Accuracy of voltage measurement ± 0.6% or ± 20 mV
• The input impedance for all analog signals is greater than
10 kΩ
The input has protection from a disconnected cable using a 70 kΩ
pull-up resistor. If the cable is not connected, input voltage is
10.7 V, which causes the generator to pull back output power down
to 0 W.
Bias Voltage Out
output
characteristics
Output specification for this SMA connector:
• Output voltage range 0 V to -5 V
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Specifications
3‑9
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...