RETURNING UNITS FOR REPAIR
Before returning any product for repair and/or adjustment, first follow all
troubleshooting procedures. After following troubleshooting procedures, if your unit
is unable to resume normal operation, contact AE Global Services and discuss the
problem with a representative. Be prepared to give them the model number and serial
number of the unit as well as the reason for the proposed return. This consultation
call will allow Global Services to determine if the unit must actually be returned for
the problem to be corrected. Such technical consultation is always available at no
charge.
Purging Water for Transport or Storage
Before transporting or storing water-cooled units, you must first purge water from the
unit. Failure to do so can result in damage to the unit and will void the unit warranty.
DANGER:
RISK OF DEATH OR BODILY INJURY. Disconnect and lockout/tagout all
sources of input power before working on this unit or anything connected to
it.
CAUTION:
Purge all water from the unit before shipping. Failure to do so can result in
damage to the unit during shipping and will void the unit warranty.
To purge water from the unit:
1. Uninstall the unit and, if applicable, remove the unit from the rack.
2. Apply compressed air to the water intake connector. Water will exit through the
water outflow connector.
3. Apply compressed air until water no longer exits the water outflow connector.
If you need additional information on how to purge water from the unit, contact
AE Global Services.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Troubleshooting and Global Services
6‑16
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...