Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
2
RF On
Turns RF output on if there are no active or
latched faults or warnings. Accepted only
when host control mode is active.
Command
162
reports this value.
0
1
3
set regulation mode
Sets the regulation mode.
Send 1 data byte (8-bit value):
• 6 = Forward
• 7 = Delivered or load
• 8 = External (DC bias)
Command
154
reports this value.
1
1
4
set user power limit
Sets the user power limit. You cannot change
the power limit while the unit is on. Valid
values are from the low power limit to the
unit maximum power.
The user power limit is directly related to the
active regulation mode. For example, when in
load regulation mode, the user power limit
will limit delivered power.
Send 2 data bytes (16-bit value) = Power limit
in watts
Command
169
reports this value.
2
1
5
set user reflected
power limit
Sets the user reflected power limit in watts.
The user reflected power limit affects all
regulation modes. The unit retains the user
reflected power limit as long as power is
applied. If power is cycled, the reflected
power limit returns to the default value, the
specified reflected power maximum.
You cannot change the user reflected power
limit while the output is on. Valid values are
from the specified reflected power minimum
to the specified reflected power maximum.
Send 2 data bytes (16-bit value) = Reflected
power limit in watts
Command
170
reports this value.
2
1
6
set user external
feedback limit
Sets the user external feedback limit in volts.
The user external feedback limit affects only
the external DC bias regulation mode. The
2
1
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑21
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...