Table 4‑3. 25-pin User port pin descriptions (Continued)
Signal
Pin
Related
Pin
Name
Signal
Type
Description
19
GROUND
Signal/chassis ground.
20
Not connected.
21
GROUND
Signal/chassis ground.
22
9
OVERTEMP
Digital
output
When an internal overtemperature
shutdown condition is detected, a low
(opto-coupler output) impedance is
created between this pin and pin 9.
See
‑
10 for the
wiring diagram.
23
10
INTERLOCK
LOOP RETURN
See pin 10.
24
11
DC BUS OK
Digital
output
When the interlocks are satisfied and no
faults are present, a low (opto-coupler
output) impedance is created between
this pin and pin 11.
See
‑
10 for the
wiring diagram.
25
Not connected.
WIRING DIAGRAMS FOR THE 25-PIN USER PORT
The diagrams in this section provide wiring information to connect to the 25-pin
User
port.
3034
_
+
1000 pF
1000 pF
OP400
2
15
10 H
m
10 H
m
User
Unit
Voltage Measurement Device
(see pin description
for scaling)
Pin 15 must
be grounded
Figure 4‑2. REFL PWR MONITOR (pins 2 and 15)
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑6
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...