Table 5‑2. HARTING 70 A connector part numbers
HARTING Part
Number
Quantity
Description
09 14 006 0303
1
HARTING frame
09 30 006 0301
1
HARTING housing mounting
09 14 002 2642
2
HARTING 70 A insert
TO CONNECT AC INPUT POWER WITH THE HARTING
CONNECTOR
DANGER:
RISK OF DEATH OR BODILY INJURY. Disconnect and lockout/tagout all
sources of input power before working on this unit or anything connected to
it.
WARNING:
This device must be installed so that the input power connection is
inaccessible to the user.
CAUTION:
To provide the required overcurrent protection, install and operate this device
with a 50 A (maximum) circuit breaker switch on the AC input. The circuit
breaker switch must be easily accessible and near the device.
CAUTION:
This equipment is intended for use with a single source of 3-phase power
with all phases vectored at 120º angles ± 5º. If the equipment is used with an
uninterruptable power supply (UPS), or other type of power conditioner, the
user is responsible to guarantee the safety and EMC performance of the
entire system.
1. Ensure that the AC line to which you are connecting the unit is a balanced,
three-phase AC line that complies with the input specifications.
All phases must be vectored at 120° angles ± 5°.
☞
Important
Connection to an unbalanced line could negatively impact the dynamic
performance of this device and its viable range of operation.
2. Ensure that the AC power circuit breaker to the connector is switched off.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Installation, Setup, and Operation
5‑14
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...