Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Send 6 data bytes.
• Bytes 0 and 1 = 5 (set memory mode)
• Bytes 2 and 3 = Memory mode
◦ 0 = RAM
◦ 1 = NVRAM
• Bytes 4 and 5 = Reserved
Command
172
B0 = 5 reports these values.
31
set setpoint ramping
configuration
Sets the setpoint ramping mode and ramp
parameters or sets ramping memory mode.
The ramp up and down parameters can be set
independently.
Send 6 or 8 data bytes. Sending 6 data bytes
allows you to set the setpoint ramping mode
and ramp parameters. Sending 8 data bytes
allows you to select a subcommand, and then
set the setpoint ramping mode and parameters
or set the ramping memory mode.
Ramping Mode and Parameters
In W/s mode, the ramp parameters represent
the ramp rate in watts per second. The
acceptable range for the ramp up and ramp
down parameters in W/s mode is 1 W/s to
65535 W/s.
In timed mode, the ramp parameters represent
the time in ms. The acceptable range for the
ramp up and ramp down parameters in timed
mode is 1 ms to 65535 ms.
The setpoint ramp parameters can be set while
output is on. The ramp parameters are not
allowed to change during a setpoint ramp that
is currently in progress. The setpoint will not
be ramped in either mode if the setpoint
change is less than 1 W.
6 Data Byte Version
Send 6 data bytes (three 16-bit values):
• Bytes 0 and 1 = Ramp mode
6 or 8
1
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑25
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...