Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
◦ 1 = W/s
◦ 2 = Timed (in ms)
• Bytes 2 and 3 (16-bit value) = Ramp up
(in W/s or time in ms)
• Bytes 4 and 5 (16-bit value) = Ramp
down (in W/s or time in ms)
2 Data Byte Version
Send 2 data bytes (16-bit value) indicating the
parameters to return.
• 1 = Ramp mode and parameter data
• 2 = Ramp memory mode
Returns 8 data bytes:
• If you send a value of 1 = Get ramp data
◦ Bytes 0 and 1 = 1 (Ramp mode and
parameter data selection)
◦ Bytes 2 and 3 = Ramp mode (0 =
Disabled, 1 = W/s, 2 = ms)
◦ Bytes 4 and 5 = Ramp up (in W/s or
time in ms)
◦ Bytes 6 and 7 = Ramp down (in W/s or
time in ms)
• If you send a value of 2 = Get memory
mode
◦ Bytes 0 and 1 = 2 (ramp memory mode
selection)
◦ Byte 2 and 3 = Memory mode (0 =
RAM, 1 = NVRAM)
◦ Bytes 4 through 7 = Return 0
Set this value with command
31
.
154
report regulation
mode
Reports the active regulation mode.
Send 0 or 1 data bytes.
Send 0 data bytes:
0 or 1
1 or 2
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑45
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...