Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
◦ 0 = Diagnostics in progress
◦ 1 = Diagnostic test complete – passed
◦ 2 = Diagnostic test complete – failed
◦ 3 = Diagnostic test interrupted
◦ 4 = Diagnostic mode disabled
• Byte 1 = Failure status (bit flags)
◦ Bit 0 = Forward power
◦ Bit 1 = Rectified bus voltage
◦ Bit 2 = Test voltage
◦ Bits 3 through 7 = Unused
• Bytes 2 through 4 = Unused
• Byte 4 = Unused
248
report operating
parameters
This command allows you to send
subcommands that report a variety of
operating parameters. Send a value in the first
two bytes that selects the parameter to report.
The subcommands are 16-bit commands
ranging in value from 1 to 65535.
Your unit may not have all the features in this
list. If you issue a command for a feature that
your unit does not have, the unit returns CSR
12, Feature Not Available.
Byte 0 =
Subcommand
1
Report frequency step
minimum
2
Report frequency step
maximum
3
Report step up gain
4
Report step down gain
6
Report gamma threshold
high
7
Report gamma threshold
low
variable
variable
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑59
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...