Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
◦ Bits 4 through 6 = Reserved
◦ Bit 7 = Interlock (0 = interlock closed,
1 = interlock open)
• Byte 2:
◦ Bits 0 and 1 = Reserved
◦ Bit 2 = High AC line voltage warning
(1 = Warning)
◦ Bit 3 = Reserved
◦ Bit 4 = Low AC line voltage warning
(1 = Warning)
◦ Bit 5 = Protection Limit (1 = Limit
active)
◦ Bits 6 and 7 = Reserved
• Byte 3:
◦ Bit 0 = Reserved
◦ Bit 1 = Inverter not ready (1 = Not
ready)
◦ Bit 2 = Reserved
◦ Bits 3 and 4 = Reserved
◦ Bit 5 = Fault present (0 = No faults, 1
= Faults exist)
◦ Bit 6 = Warning present (0 = No
warnings, 1 = Warnings exist)
◦ Bit 7 = Reserved
When either of the fault present or warning
present bits are set, one or more active or
latched faults or warnings currently exist in
the unit. You can obtain a list of current faults
or warnings by issuing command
223
with
the appropriate parameter.
164
report setpoint and
regulation mode
Reports the output setpoint set with command
8
and the output regulation mode set with
command
3
. Reports the setpoint value in
watts when operating in forward or delivered
power regulation modes. If the unit is in DC
bias regulation mode, the setpoint is returned
0
3
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑49
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...