Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
• Bytes 0 and 1 = 23 (set tuning gain
delay)
• Bytes 2 and 3 = Tuning gain delay
Command
248
reports this value; B0 =23.
118
set DC bias
operating mode
(subcommand 50)
Sets the following parameters:
• Power limit setting for external (DC bias)
regulation mode—when operating in
external (DC bias) regulation mode, the
unit uses an internally set value as a
maximum output power limit. In some
units, this parameter is hard coded to
limit forward power. Units that have the
power limit setting for external
regulation mode allow you to set the
power limit to either forward or delivered
power.
• SOA mode—Enables/disables the safe
operating area feature.
• Memory mode—Sets whether these
settings are volatile or nonvolatile. When
set to volatile, the settings will default to
factory default settings when power to
the unit is cycled. See the product
specifications for factory default settings.
Send 6 data bytes.
• Bytes 0 and 1 = 50 (set DC bias
operating mode)
• Bytes 2 and 3 = Select parameter to set:
◦ 1 = DC bias mode
◦ 2 = SOA mode
◦ 3 = Memory mode
• Bytes 4 and 5 = Command data
(dependent on selection in previous two
bytes)
If you selected DC bias mode:
◦ 1 = Forward power limit
6
1
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑37
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...