Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Returns 1 data byte (8-bit value):
• 6 = Forward
• 7 = Delivered or real
• 8 = External (DC bias)
Optional: Send 1 data byte (with a value of 0).
Returns 2 data bytes (16-bit value):
• Byte 1:
◦ 6 = Forward
◦ 7 = Delivered or real
◦ 8 = External (DC bias)
• Byte 2 = 0
Set this value with command
3
.
155
report active control
mode
Reports the active control mode.
Send 0 or 1 data bytes.
Send 0 data bytes:
Returns 1 data byte (8-bit value):
• 2 = Host
• 4 =
User
port (analog)
• 8 = Diagnostic
Optional: Send 1 data byte (with a value of 0).
Returns 2 data bytes (16-bit value):
• Byte 1:
◦ 2 = Host
◦ 4 =
User
port (analog)
◦ 8 = Diagnostic
• Byte 2 = 0
Set this value with command
14
.
0 or 1
1 or 2
158
report retuning
threshold
Reports the tuning criteria level at which the
tuning algorithm determines that the generator
requires retuning. The unit stores this
parameter in nonvolatile memory.
0
4
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑46
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...