Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
248
report gamma
threshold low
(subcommand 7)
Reports the gamma threshold low used during
the tuning process. The generator first
attempts to achieve a tuning criteria less than
the low threshold. If it fails, it tries the high
threshold next, after the maximum tuning
counter has expired.
Send 2 data bytes.
• Bytes 0 and 1 = 7 (report gamma
threshold low)
Returns 2 data bytes:
• Bytes 0 and 1 = Gamma threshold low
(unsigned short)
Set this value with command
118
; B0 = 7.
2
2
248
report maximum
tuning count
(subcommand 8)
Reports the maximum tuning count used
during the tuning process. This reports the
number of attempts to tune to the low
threshold before giving up and trying the high
threshold.
Send 2 data bytes.
• Bytes 0 and 1 = 8 (maximum tuning
count)
Returns 2 data bytes:
• Bytes 0 and 1 = Maximum tuning count
(unsigned short)
Set this value with command
118
; B0 = 8.
2
2
248
report tuning step
time
(subcommand 22)
Reports tuning step time. Valid values range
from 8 μs to 4096 μs.
Send 2 data bytes.
• Bytes 0 and 1 = 22 (tuning step time)
Returns 2 data bytes.
• Bytes 0 and 1 = Tuning step time in μs.
Set this value with command
118
; B0 = 22.
2
2
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑62
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...