Table 4‑3. 25-pin User port pin descriptions (Continued)
Signal
Pin
Related
Pin
Name
Signal
Type
Description
the RF output. Logic low disables the RF
output in either user control mode or host
control mode.
☞
Important
The interlocks must be satisfied
and the set point must be within
the output power range before
unit will deliver power.
on page 4
‑
7 for the
wiring diagram.
5
18
SET POINT
Analog
input
This pin linearly controls the RF output
of the generator in either forward power
mode or load power mode.
• 0 V to 10 V = 0 W to maximum
rated output power
This input also provides set point in the
voltage control mode.
• 0 V to 10 V = 0 V to 2000 V peak
to peak
on page 4
‑
7 for the
wiring diagram.
6
19
DC BIAS/
POWER
REGULATION
Digital
input
This pin switches the regulation mode of
the generator.
When logic low is applied to this pin, or
if there is no connection to this pin, the
generator regulates output power (either
forward or load, as defined by the signal
on pin 8).
When logic high is applied to this pin,
the generator regulates in the voltage
control mode.
See
on page 4
‑
8 for the
wiring diagram.
7
Not connected.
8
21
FWD/LOAD
PWR
REGULATION
Digital
input
Applying logic high to this pin causes
the generator to regulate on load power.
Logic low or no connection to this pin
causes the generator to default to
forward power regulation.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑4
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...