Table 6‑2. Fault codes (Continued)
Fault Code
Problem Description
Suggested Action
• A temperature sensor has
failed
If the fault persists, contact AE
Global Services.
54
Onboard Power Fault
Latching fault
• A voltage regulator has
failed
Cycle AC power to the unit.
If the fault persists, contact AE
Global Services.
55
Measurement FPGA Version
Fault
Internal, unrecoverable fault
• Hardware configuration
fault
Cycle AC power to the unit.
If the fault persists, contact AE
Global Services.
70
Auxiliary Temperature Fault
Latching fault
• Auxiliary temperature is
higher than 70°C (158°F)
1. Verify ambient
temperature at air inlet
on the rear panel.
2. Verify that there is no
obstruction within
100 mm (4″) of the air
inlet panel on the back of
the unit.
If the fault persists, contact AE
Global Services.
71
Auxiliary Cap bank
Temperature Fault
Latching fault
• Cap bank temperature is
higher than 75°C (167°F)
1. Verify ambient
temperature at air inlet
on the rear panel.
2. Verify that there is no
obstruction within
100 mm (4″) of the air
inlet panel on the back of
the unit.
If the fault persists, contact AE
Global Services.
72
Auxiliary Coldplate
Temperature Fault
Latching fault
• Auxiliary coldplate
temperature is higher
than 63°C (145°F)
1. Verify ambient
temperature at air inlet
on the rear panel.
2. Verify that there is no
obstruction within
100 mm (4″) of the air
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Troubleshooting and Global Services
6‑12
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...