Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
unit retains the user external feedback limit as
long as power is applied. If power is cycled,
the external feedback limit returns to the
default value, 2000 V.
You cannot change the user external feedback
limit while the output is on. Valid values are
from 1% of the maximum external feedback
value minimum up to the maximum external
feedback value (set with command
9
).
Send 2 data bytes (16-bit value) = External
feedback limit in volts
Command
171
reports this value.
7
restore factory
defaults
Restores all nonvolatile RAM values to the
factory preset values. See individual product
specifications for factory default parameters.
For more information, contact AE Global
Services.
Send 2 data bytes (16-bit value):
• 0 = Restore all default values
2
1
8
set power setpoint
Sets a power setpoint in watts. Sets a setpoint
in volts when operating in external (DC bias)
regulation mode. Setpoint cannot be greater
than the unit's maximum output power or the
user power limit. Setpoint cannot be greater
than the maximum external feedback value
when in external regulation mode.
• User power limit = Set with command
4
Accepted only when host control mode is
active.
Send 2 data bytes (16-bit value) = Power
setpoint in watts.When operating in external
(DC bias) regulation mode, the setpoint is in
volts.
Command
164
reports this value.
2
1
9
set maximum
external feedback
value (NV)
Sets the maximum external feedback value in
volts. This setting only affects the unit in the
external (DC bias) regulation mode. The unit
stores the maximum external feedback value
in nonvolatile memory. You cannot change the
3
1
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑22
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...