Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Returns a nonterminated 9-character ASCII
string that represents the power supply type
(
PT-MF
).
Send 1 data byte:
• Byte 0 = 3
Returns 10 bytes:
• Bytes 0 through 3 = 4 ASCII characters
• Bytes 4 through 9 = Six-digit ASCII
representation of the 3 least significant
bytes of the unit MAC ID.
129
report power supply
size
Reports the power supply size in kW, in four
or six digits, depending on the sent data bytes.
Send 0 or 1 data bytes.
Send 0 data bytes:
• Returns four data bytes = Power supply
size formatted to four ASCII characters.
Optional: Send 1 data byte (with a value of 0):
• Returns six data bytes = Power supply
size formatted to six ASCII characters,
right justified.
0 or 1
4 or 6
ASCII
characters
130
report software part
number
Reports the software part number. Returns a
nonterminated ASCII string that represents the
AE software part number (for example,
“7432006”). You can use this number in
conjunction with the revision number returned
by command
198
to identify the software in
the unit.
Sending a request data byte is optional. You
can send 0 data bytes or 1 data byte.
Send 0 data bytes.
• Returns Coldfire application firmware
part number.
0 or 1
7 ASCII
characters
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑39
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...