Table 4‑3. 25-pin User port pin descriptions (Continued)
Signal
Pin
Related
Pin
Name
Signal
Type
Description
In voltage control mode, this pin is
ignored.
See
on page 4
‑
8 for the
wiring diagram.
9
22
OVERTEMP
RETURN
Digital
output
See pin 22.
10
23
INTERLOCK
LOOP
This pin should connect to pin 23 to
complete the interlock chain. If the
interlock chain is broken, the unit will
not operate. External circuit should be
capable of switching 50 mA at 24 VAC.
Maximum allowed resistance of the
interlock chain is 75 Ω.
See
on page 4
‑
9 for the
wiring diagram.
11
24
DC BUS OK
RETURN
Digital
output
See pin 24.
12
Not connected.
13
21
+15 VDC
Analog
output
User voltage for interface purposes.
Rated 400 mA maximum. Short-circuit
protected.
See
on page 4
‑
9 for the
wiring diagram.
14
1
SET POINT
STATUS
Digital
output
When the generator is out of set point by
more than 1% and 3 W, a low (opto-
coupler output) impedance is created
between this pin and pin 1.
See
‑
9 for the
wiring diagram.
15
2
RFL POWER
MONITOR
RETURN
Analog
output
Signal return for pin 2.
16
3
FWD/LOAD
PWR MONITOR
RETURN
Analog
output
Signal return for pin 3.
17
4
RF PWR ON
RETURN
Digital
input
Signal return for pin 4.
18
5
SET POINT
RETURN
Analog
input
Signal return for pin 5.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑5
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...