ELECTRICAL SPECIFICATIONS
☞
Important
AE Host command
7
restores all nonvolatile RAM values to factory preset
values. See individual product specifications for factory default parameters.
For more information, contact AE Global Services.
Table 3‑2. Electrical specifications
Description
Specification
Input Power
Standard operation
• Nominal: VAC = 208 V, 60 Hz; Low line AC: VAC = 187 V,
60 Hz
• Output power = 2000 W
• Frequency = 400 kHz
• Load = 50 Ω
AC facility requirements
• Line voltage
• Line frequency
• Phase
Facility requirements specification:
• Line voltage: 208 VAC ± 10% (187 VAC to 229 VAC)
• Line frequency: 50 Hz to 60 Hz nominal (47 Hz to 63 Hz)
• Phase: 3φ with ground, no neutral
AC to RF efficiency
Nominal: 78%
Low line AC: 79%
AC input power factor
Nominal: 0.67
Low line AC: 0.69
AC power consumption
Nominal: 2556 W
Low line AC: 2514 W
AC line current
< 16 A
RMS
per phase at 2000 W, 208 VAC
< 18 A
RMS
per phase at 2000 W, low AC line
Overcurrent protection
50 A circuit breaker with lockout pin
RF Output Power
Warm-up time
Generator minimum warm-up time of 2 minutes after AC on
Frequency tuning range
360 kHz to 440 kHz
Frequency stability
< 50 ppm of selected frequency
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Specifications
3‑3
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...