Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Since each interface has a unique watchdog
timer, the value reported is the value of the
watchdog timer associated with that specific
interface.
Send 1 data byte with a value of zero.
Returns 2 data bytes.
• Bytes 0 and 1 = Watchdog timer value in
ms (16-bit value).
Set this value with command
39
.
140
report host time-out
Reports the current host port time-out value
for the serial port.
Host port time-out value is the maximum time
allowed between bytes received. This value is
in units of 10 ms. The allowable range of
values is from 2 to 500, representing 20 ms to
5.00 seconds.
Returns 2 data bytes (16-bit value):
• Bytes 0 and 1 = Host port time-out value.
Set this value with command
40
.
0
2
144
report minimum
tuning frequency
Reports the minimum frequency that the
generator uses for automatic tuning. The
minimum tuning frequency must be within the
unit’s factory-set frequency range. The unit
stores this parameter in nonvolatile memory.
Send 0 data bytes to return frequency in kHz,
or send 1 data byte to return frequency in kHz
or Hz.
Send 0 data bytes:
• Returns 4 data bytes = Frequency in kHz
Send 1 data byte:
• Byte 0 = Frequency in kHz or Hz
◦ 0 = Returns frequency in kHz
◦ 1 = Returns frequency in Hz
Returns 4 data bytes = Frequency in kHz or
Hz
0 or 1
4
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑41
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...